Product Information
About Us
Customer Support
Contact
 

Home > Focus on! > Sealant for clean rooms > Test of organic compound adsorption to Si wafer

By Product type

By function and usage
By Product name
Focus on!
Focus on!

Test of organic compound adsorption to Si wafer(substrate surface adsorption-thermal desorption method: JACA, No.34)


Measurement method
  • Uncured sheets of sealant (100 mm×100 mm×1 mm) were cured for 7 days at 23°C/50% RH. Polished wafer chips were placed with the sealant sample inside a glass desiccator (approx. 5 liter) such that the wafer did not touch the sealant. They were left in the desiccator for 24 hours. Next, the wafer chips were removed and heated in a purge-and-trap headspace sampler, and the desorbed gases were analyzed using GC-MS.

Measurement results

Total amount of adsorbed organic compounds by calculation(Corresponding value n-C16H34)
(Units: ng/cm2)
 

Pure Sealant

Pure Sealant
S-type

Our conventional Sealant

Reduced LMW Sealant*

Siloxane

0.01 >

0.01 >

1.7

0.34

Other than Siloxane

1.40

0.04

1.8

1.39

Total organic compounds

1.40

0.04

3.5

1.73

* Competitor's product (not specified values)